PULSE=DISABLE_SINGLE_PULSE, SELECT=CTIN_3, INV=NOT_INVERTED, SYNCH=DISABLE__SYNCHRONIZ, EDGE=NO_EDGE_DETECTION
SCT CTIN_3 capture input multiplexer (GIMA output 19)
| INV | Invert input 0 (NOT_INVERTED): Not inverted. 1 (INPUT_INVERTED): Input inverted. |
| EDGE | Enable rising edge detection 0 (NO_EDGE_DETECTION): No edge detection. 1 (RISING_EDGE_DETECTIO): Rising edge detection enabled. |
| SYNCH | Enable synchronization 0 (DISABLE__SYNCHRONIZ): Disable synchronization. 1 (ENABLE__SYNCHRONIZA): Enable synchronization. |
| PULSE | Enable single pulse generation. 0 (DISABLE_SINGLE_PULSE): Disable single pulse generation. 1 (ENABLE_SINGLE_PULSE): Enable single pulse generation. |
| SELECT | Select input. Values 0x4 to 0xF are reserved. 0 (CTIN_3): CTIN_3 1 (USART0_TX_ACTIVE): USART0 TX active 2 (RESERVED): Reserved 3 (RESERVED): Reserved |
| RESERVED | Reserved |